We can help you Select the Best MERV 8 & MERV 11 Polypropylene HVAC air filter for your school based on Static Pressure, Wattage and >0.5 micron particle efficiency.
Static Pressure
Air Handler |
0.1"WG | to | 1.0"WG |
>0.5 micron particle efficiency/ ft3 | 5000 Particles/ft3 | to | 1 Million Particles/ft3 |
Wattage | 100 Watts | to | 1800 Watts |
Air Filter Size | 20 x 20 x 1" | 20 x 20 x 2" | 20 x 20 x 4" |
Air Flow | 317 FPM (836 CFM) | 397 FPM (1050 CFM) | 464 FPM (1225 CFM) |
Test for Useful Life of an air
filter.
Months of service |
New Air Filters | 1, 2 months of service | 3, 4 months of service |
*
Air Conditioning accounts for 40% to 60% of the electricity used in School Buildings.
*
The Best
School Air Filter is our 100% Polypropylene Pleated Air Filter.
Saves Electricity and Cleans the air of lung damaging dust size particles. Cleaner air with NO modification required to the air filter rack or blower motor. |
![]() |
||||
2 inch Commercial Air Filters - Comparison Wattage & 0.5 Micron Particle Count Efficiency. | |||||
2 Inch Air Filter | 1050 CFM
400 FPM |
"WG STATIC
PRESSURE Air Handler |
WATTS GE 2.5 ECM MOTOR |
Electricity Cost is $0.14/KWHr & 2500 hours / year | EFFICIENCY @ 0.5 microns |
NO AIR FILTER | 1050 CFM
400 FPM |
0.21" WG SP Air Handler |
228 WATTS
GE 2.5 ECM MOTOR |
No Air Filter
$79.80 / Year 570 KWHr |
*1050 @ 0.5 microns base line |
MERV 8
Polypropylene Pleated Air Filter
0.19" WG @ 400 FPM |
1050 CFM
400 FPM |
0.41" WG
SP Air Handler |
272 WATTS GE 2.5 ECM MOTOR |
$95 / Year 680 KWHr LOWEST Electricity Operating Cost |
13% EFFICIENCY (915/1050) @ 0.5 microns |
GlasFloss PTA Fiberglass Air Filter
"PolyStrand" 0.23" WG @ 400 FPM
|
1050 CFM
400 FPM |
0.44" WG SP Air Handler |
280 WATTS
GE 2.5 ECM MOTOR |
$98 /
Year
700 KWHr |
1% EFFICIENCY (1040/1050) @ 0.5 microns |
MERV 11 2 inch pleat 0.26" WG @ 400 FPM |
1050 CFM
400 FPM |
0.47" WG SP Air Handler |
285 WATTS
GE 2.5 ECM MOTOR |
$100 /
Year
712 KWHr |
20% EFFICIENCY (3020/3773) @ 0.5 microns |
MERV 11 2 inch pleat 0.27" WG @ 400 FPM |
1050 CFM
400 FPM |
0.48" WG SP Air Handler |
288 WATTS
GE 2.5 ECM MOTOR |
$101 /
Year
720 KWHr |
54% EFFICIENCY (1726/3735) @ 0.5 microns |
MERV 8
Cotton / Polyester Pleated Air Filter 0.32" WG @ 400 FPM |
1050 CFM
400 FPM |
0.52" WG SP Air Handler |
300 WATTS
GE 2.5 ECM MOTOR |
$105 /
Year
750 KWHr |
6% EFFICIENCY (990/1050) @ 0.5 microns |
MERV 8 Polyester Air Filter Pad 1.5 inch 0.42" WG @ 400 FPM |
1050 CFM
400 FPM |
0.63" WG SP Air Handler |
322 WATTS
GE 2.5 ECM MOTOR |
$112.70
/ Year
805 KWHr Highest Electricity Operating Cost |
3.5% EFFICIENCY (1014/1050) @ 0.5 microns |
*
My Polypropylene Pleated Air Filter cleans the 0.5 micron size particles from the air and costs less to use than a Fiberglass Air Filter. Watch the Videos.
*
Play the 2 videos together at the same time! Adjust the volume! | Play the 2 videos together at the same time! MUTE the volume! |
*
Replace your Polyester Pad and Polyester Link Air Filters with our 2 inch Polypropylene Pleated Commercial Air Filter and save your school $16 - $27 per air filter per year depending on the air velocity FPM and Clean the air 2- 12 times better on 0.5 micron size particles. | |
![]() Polyester Pad School Air Filter |
![]() Polyester 2 Ply Link Filter |
*
My 2 inch Polypropylene Air Filter Replaces all the 2 inch commercial air filters on the market. It delivers cleaner air than Fiberglass, Polyester Pads, and Cotton / Polyester Blend Pleated Air Filters at 0.5 microns. Saves Money and uses less wattage to clean the air. Watch the Videos.
*
Play the 2 videos together at the same time! Adjust the volume! | Play the 2 videos together at the same time! MUTE the volume! |
*
Testing air filters can saves you money. Most air filters are changed out to soon. My filter testing service prevents replacing air filters that still have useful life.
*
Play the 2 videos together at the same time! Adjust the volume! | Play the 2 videos together at the same time! MUTE the volume! |
Testing air
filters can saves you money. Most air filters are changed out to
soon. Here I measure a 1 month old dirty air filter for wattage and
particle count. The Air Filter should have been left in the system for
another month. My filter testing service prevents replacing air
filters that still have useful life. I can save you money on unnecessary air filter changes. I can test an air filter after it's been in service for 1 month, 2 months, or 3 months and determine if it needs to be replaced based on wattage / energy cost or particle count at 0.5 microns. |
*
Air Janitor TM
Polypropylene Pleated Air
Filter 2 inch Polypropylene MERV 8
Cleaner air with NO modification required to the air filter rack or the blower motor. |
|
![]() Polypropylene Pleated Air Filter MERV 8 13% Efficient on >0.5 micron Particles Measured at 397 FPM 0.15"WG SP @ 317 FPM Measured 143 Watts GE 2.5 ECM Motor 0.20"WG SP @ 397 FPM Measured 272 Watts GE 2.5 ECM Motor |
Air Filter Sizes
Available 12 x 20 x 2 Air Janitor TM Air Filter filters >0.5 micron lung damaging dust size particles from the air every time the air passes through the air filter (Air Change every 10 minutes). |
*
Indoor Air Quality Study Reveals The Best School HVAC MERV 8 Air Conditioning Air Filter! Most Schools use $2 throwaway polyester air filter pads that do not filter the air below 1 micron. The 0.5 micron particles from bus fumes are a lung damaging dust that reach the students lungs and triggers asthmatic attacks.Asthma is the most common childhood disease. 9 million school age children in America have asthma. Air filtration media fabric has changed in the last few years. 4 different types of air filter media fabric were tested at 0.5 microns using a Dylos Air Quality Monitor. Fiberglass Air Filters, Polyester Pads & Links used in most schools and office buildings, Cotton / Polyester Blend pleated air filters & 100% Polypropylene pleated air filters. The 100% Polypropylene Pleated Air Filter filtered the air best. Test the Polypropylene Air Filters with Dylos Laser Particle Counter in your air handlers! Just install a few Air Janitor Polypropylene Pleated 2" Air Filters in your air handlers and use Dylos Air Quality Monitor to measure the drop in >0.5 micron particles in the air. |
*
School Indoor Air Pollution Sources are from Outdoor Makeup Air (15 CFM / Student), School Bus Fumes, and 5 minute class change. | |
![]() |
Outdoor Air Pollution enters
the school through the school entrance. School buses bring students to the school in the morning and the fumes from the diesel buses get sucked into the school building. |
![]() |
This Dylos Air Quality Monitor Model DC1100 Laser Particle Counter Shows a Reading of 11,122 at 7:36 AM on 08/26/2008. The Air Particle Count is over a million particles per cubic foot (1,112,200 Particles / Ft3) at >0.5 microns. These Lung Damaging Dust Size Particles enter the school through the school entrance and makeup / fresh air ducts.
|
*
5 Minute Class Change | |
![]() |
Indoor air pollution is created in the hallway during the 5 minute class change. |
![]() |
During the 5 minute class change, a student will breathe in more particles that reach the Lungs Alveoli. |
*
MERV 8 Filter HOME PAGE | email americanallergy@yahoo.com
*
Measuring Energy Saving HVAC Air
Filters Residential and Commercial Air Filtration Designing an Energy Saving air filter that cleans the air of 0.5 micron particles. Air Filter Static Pressure, Air Flow CFM,
Wattage, and IAQ particle count are measured. |
|
Air Janitor Polypropylene Energy
Saving Pleated Air Filter filters the air of 0.5 micron particles.
Dirty Air Filters restrict the air flow and cost more money to use the air conditioning system. I show how the air is cleaned of 0.5 micron size particles from the air using the Dylos Air Quality Monitor laser particle counter. |
*
Air Filter Energy Comparison / Calculator for Annual Air Filter Cost (xls file) |
http://www.kcfiltration.com/resource/calculator/KC_calc.html |
*
HOME PAGE | IAQ PUBLIC SCHOOLS | ENERGY SAVING AIR FILTERS | DYLOS AIR QUALITY MONITOR | email americanallergy@yahoo.com
03/28/2012
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Air Janitor Polypropylene Pleated Air Filter
Energy Efficient Air Filter for Improved Indoor Air Quality
American Allergy Supply Home Page
For 2 inch Commercial Office & School Polypropylene Air Filters Click Here! www.merv8.com
Air Janitor Polypropylene Energy Saving Pleated Air Filter filters the air of 0.5 micron particles. You Tube Video - Adjust the Volume | |
Dirty Air Filters restrict the air
flow and use more electricity to cool your home. I show how clean the air is using my air filter. The Dylos Air Quality Monitor laser particle counter shows fewer 0.5 micron size particles in the air using my air filter. |
*
![]() |
Air Janitor TM Polypropylene Pleated Air Filter A New Air Janitor TM Air Filter filters >0.5 micron lung damaging dust size particles from the air everytime the air passes through the air filter (Air Change every 10 minutes). Cleans the air inside your home in a few hours! |
Air Janitor TM Polypropylene Pleated Air Filter |
Designed to filter >0.5
micron size lung damaging dust particles that reach the lung’s alveoli
and triggers asthmatic attacks. For Schools, Office Buildings, and Residential Homes. |
*
Air Janitor Charcoal TM Polypropylene / Charcoal Blend Pleated Air Filter Charcoal Air Filters for Pets & Chemical Odors! |
Designed to filter >0.5
micron size lung damaging dust particles that reach the lung’s alveoli
and triggers asthmatic attacks. For Schools, Office Buildings, and Residential Homes. |
*
Indoor Air Quality Study Reveals The Best School Air Conditioning Air Filter! |
Most Schools use $2 throwaway
polyester air filter pads that do not filter the air below 1 micron. The
0.5 micron particles from bus fumes are a lung damaging dust that reach
the students lungs and triggers asthmatic attacks. Asthma is the most common childhood disease. 9 million school age children in America have asthma. Air filtration media fabric has changed in the last few years. 4 different types of air filter media fabric were tested at 0.5 microns using a Dylos Air Quality Monitor ($250).Fiberglass Air Filters, Polyester Pads & Links used in most schools and office buildings, Cotton / Polyester Blend pleated air filters & 100% Polypropylene pleated air filters. The Polypropylene Pleated Air Filter filtered the air best. Just install our Air Janitor Polypropylene Pleated Air Filter and use Dylos Air Quality Monitor to measure fewer 0.5 micron particles in the air your students will be breathing each day! Sandy Reifler www.AmericanAllergySupply.com |
*
Indoor Air Quality in Texas Schools
![]() |
Students at Pin Oak Middle School and Houston Independent School District. The school and district have enrolled more than 50 students displaced by Hurricane Katrina. |
*
![]() |
Secretary Spellings with Texas Governor Perry, ED Assistant Secretary Simon, ED Assistant Secretary Sullivan, and staff and students of Pin Oak Middle School and Houston Independent School District. The school and district are serving more 50 students displaced by Hurricane Katrina. |
*
TEXAS has 18 school districts in the top 100 largest school districts in the USA serving 1.3 million students.
The Houston TX area has 7 of the top 100 largest school districts and are serving 500,000 students.
*
Top 100 Largest US School Districts | Texas Ranking | Students |
Houston Independent School District | # 7 | 210,000 Students |
Dallas Independent School District | #14 | 161,000 Students |
Cypress-Fairbanks Independent School District | #35 | 86,000 Students |
Austin Independent School District | #36 | 81,000 Students |
Fort Worth Independent School District | #38 | 80,000 Students |
Northside Independent School District | #40 | 78,000 Students |
Fort Bend Independent School District | #54 | 66,000 Students |
El Paso Independent School District | #58 | 63,000 Students |
Arlington Independent School District | #59 | 63,000 Students |
North East Independent School District | #64 | 59,000 Students |
Aldine Independent School District | #70 | 58,000 Students |
Garland Independent School District | #71 | 57,000 Students |
San Antonio Independent School District | #74 | 56,000 Students |
Plano Independent School District | #78 | 53,000 Students |
Pasadena Independent School District | #89 | 49,000 Students |
Brownsville Independent School District | #94 | 48,000 Students |
Katy Independent School District | #95 | 48,000 Students |
Alief Independent School District | #99 | 47,000 Students |
*
Indoor Air Quality in Texas Schools |
Asthma is the most common
childhood disease. This picture shows that the 0.5 micron particles are
deposited deep in the Lung's Alveoli.
|
This graph shows that the
student's lungs alveoli can filter the air 18% better than the school's
air conditioning air filters.
|
*
Indoor Air Pollution from the school bus fumes and the 5 minute class change.
Outdoor Air Pollution enters the school through the school entrance. School buses bring students to the school and the fumes from the diesel bus get sucked into the school building. |
![]() |
*
5 Minute Class Change | |
![]() |
Indoor air pollution is created in the hallway during the 5 minute class change. |
![]() |
During the 5 minute class change, a student will breathe in more particles that reach the Lungs Alveoli. |
|
At a High School with 3000+ students, there were more airborne >0.5 micron particles in the hallway during class change than outdoors during rush hour traffic! |
*
Measuring Energy Saving HVAC Air
Filters Residential and Commercial Air Filtration Designing an Energy Saving air filter that cleans the air of 0.5 micron particles. Air Filter Static Pressure, Air
Flow CFM, Wattage, and IAQ particle count are measured. |
|
Air Janitor Polypropylene Energy
Saving Pleated Air Filter filters the air of 0.5 micron particles. Dirty Air Filters restrict the air flow and cost more money to use the air conditioning system. I show how the air is cleaned of 0.5 micron size particles from the air using the Dylos Air Quality Monitor laser particle counter. |
*
Air Conditioning accounts for 40% to 60% of the electricity used in US commercial buildings and residential homes.
Air Filter Energy Comparison / Calculator for Annual Air Filter Cost (xls file) |
http://www.kcfiltration.com/resource/calculator/KC_calc.html |
*
Replace your Polyester Pad and Polyester Link Air Filters with our 2 inch Polypropylene Pleated Commercial Air Filter and save your school $17.70 per air filter per year and Clean the air 2- 5 times better on 0.5 micron size particles. | |
![]() Polyester Pad School Air Filter |
![]() Polyester 2 Ply Link Filter |
*
The Best School Air Filter is our Polypropylene Pleated Air Filter. Saves Electricity and Cleans the air of lung damaging dust size particles. |
![]() |
||||
2 inch Commercial Air Filters - Comparison Wattage & 0.5 Micron Particle Count Efficiency. | |||||
2 Inch Air Filter | 1050 CFM 400 FPM |
" WG STATIC PRESSURE Air Handler | WATTS | Electricity Cost is $0.14/KWHr & 2500 hours / year | EFFICIENCY @ 0.5 microns |
NO AIR FILTER | 1050 CFM 400FPM |
0.21" WG STATIC PRESSURE Air Handler | 228 WATTS GE 2.5 ECM MOTOR |
No Air Filter $79.80 / Year 570 KWHr |
* |
Polypropylene Pleated Air Filter 0.19"WG @ 400 FPM |
1050 CFM 400 FPM |
0.41" WG STATIC PRESSURE Air Handler | 272 WATTS GE 2.5 ECM MOTOR | $95 / Year 680 KWHr LOWEST Electricity Operating Cost | 13% EFFICIENCY (915/1050) @ 0.5 microns |
GlasFloss PTA Fiberglass Air Filter 0.23"WG @ 400 FPM
|
1050 CFM 400FPM |
0.44" WG STATIC PRESSURE Air Handler | 280 WATTS GE 2.5 ECM MOTOR |
$98 /
Year 700 KWHr |
1% EFFICIENCY (1040/1050) @ 0.5 microns |
Cotton / Polyester Pleated Air
Filter 0.32"WG @ 400 FPM |
1050 CFM 400FPM |
0.52" WG STATIC PRESSURE Air Handler | 300 WATTS GE 2.5 ECM MOTOR |
$105 /
Year 750 KWHr |
6% EFFICIENCY (990/1050) @ 0.5 microns |
Polyester Air Filter Pad 1.5 inch 0.42"WG @ 400 FPM |
1050 CFM 400FPM |
0.63" WG STATIC PRESSURE Air Handler | 322 WATTS GE 2.5 ECM MOTOR |
$112.70 /
Year 805 KWHr Highest Cost |
3.5% EFFICIENCY (1014/1050) @ 0.5 microns |
*
Play the 2 videos together at the same time! Adjust the volume! | Play the 2 videos together at the same time! MUTE the volume! |
My Polypropylene Pleated Air Filter cleans the 0.5 micron size particles from the air and costs less to use than a Fiberglass Air Filter. |
*
My 2 inch Polypropylene Air Filter Replaces all the 2 inch commercial air filters on the market. It delivers cleaner air at 0.5 microns than Fiberglass, Polyester Pads, and Cotton / Polyester Blend Pleated Air Filters. Saves Money and uses less wattage to clean the air. |
*
Play the 2 videos together at the same time! Adjust the volume! | Play the 2 videos together at the same time! MUTE the volume! |
Testing an air
filter saves you money. Most
air filters are changed out to soon. Here I measure a 1 month old dirty
air filter for wattage and particle count. The Air Filter should have
been left in the system for another month. My service prevents replacing
air filters with alot of life left. I can save you money on unnecessary air filter changes. I can test an air filter after it's been in service for a month, 2 months, or 3 months and determine if it needs to be replaced based on wattage / energy cost or particle count at 0.5 microns. |
*
08/17/2008
ENERGY SAVING AIR FILTERS
![]() |
![]() |
![]() |
![]() |
![]() This polyester pad air filter looks filthy / dirty but it was changed out too soon! The only way to know when to change out an air filter is to measure it!
|
![]() |
![]() Carrier Infinity System Monitor Thermostat, "WG Static Pressure, and Air Flow CFM and Kill a Watt Meter (Watts) |
![]() Dylos Air Quality Monitor Laser Particle Counter Measures 0.5 micron Particles |
*
*
07 /29 /2010
11/07/2012